High Frequency Online UPS For Server
- Andespower or OEM brand
- Foshan, China
- 15-20 working day
- 10000units per month
- 100pcs
High Frequency Online UPS For Server
AF series high frequency online UPS is double conversion online UPS. Advance DSP digital control technology, input power factor is 0.9. Ultra-wide input voltage range. with RS232 communication port , connect UPS and computer to multi-purpose monitoring and management operations, available SNMP card(optional).
The UPS can be widely used for Personal Computer, Server and workstations, multi-media, Electronic & telecom, medical equipment and securities system.
High Frequency Online UPS For Server
Features:
Advance DSP digital control technology.
Active input power factor correction(PFC)
Frequency adaptive system
Ultra wide input voltage range
Input power factor is 0.9
Ultra wide input frequency range
Strong scalability
Green and environment protection
Specifications:
Model | AF1K | AFKL | AF2K | AF2KL | AF3K | AF3KL | AF6K | AF6KL | AF10K | AF10KL | |
Capacity | 1KVA/900 W | 2KVA/1.8KW | 3KVA/2.7KW | 6KVA/5.4KW | 10KVA/9KW | ||||||
Battery Voltage | 12V7AH*2 | 36VDC | 12V7AH*4 | 72VDC | 12V7AH*6 | 96VDC | 12V7AH*16 | 192VDC | 12V7AH*16 | 192VDC | |
Size, D*W*H(mm | 350×144×230 | 350×144×230 | 425×190×328 | 425×190×328 | 425×190×328 | 425×190×328 | 533×260×560 | 425×190×328 | 533×260×560 | 533×260×501 | |
Net Weight(kgs) | 9 | 6 | 18.4 | 10 | 23.4 | 11 | 55 | 12.2 | 62 | 21 | |
Input | |||||||||||
Input voltage | 90V-285Vac | 120-275VAC | |||||||||
Frequency Range | 40 Hz~70 Hz | 46~54 Hz or 56~64 Hz | |||||||||
Phase | Single Phase With Ground | ||||||||||
Power Factor | ≧0.99 @ 100% Load | ||||||||||
Output | |||||||||||
Output Voltage | 100/110/115/120/127 VAC or 200/208/220/230/240 VAC | 208/220/230/240 VAC | |||||||||
AC Voltage Regulation | ±1% | ||||||||||
Frequency Range(Synchronize Range) | 40~46 Hz or 54~60 Hz | 46~54 Hz or 56~64 Hz | |||||||||
Frequency Range(Batt. Mode) | 50 Hz ±0.25 Hz or 60 Hz ±0.3 Hz | 50 Hz or 60 Hz ±0.1 Hz | |||||||||
Current Crest Ratio | 3:1 | ||||||||||
Output current | 4.5A | 9.1A | 13.6A | 27A | 45A | ||||||
Harmonic Distortion | ≤3% THD(Linear Load) ≤6% THD(Non-linear Load ) | ≤3% THD(Linear Load ) ≤5% THD(Non-linear Load ) | |||||||||
Overload | 105%±5%<Load≤125%±5%:After 50secs turn to bypass and alarm ;125%±5%<Load≤150%±5%:after 25secs turn to bypass and alarm; load>150%±5%:after 300ms turn to bypass and alarm. | 105%±5%<Load≤125%±5%:After 1mins turn to bypass and alarm ;125%±5%<Load≤135%±5%:after 30secs turn to bypass and alarm; load>135%±5%:after 300ms turn to bypass and alarm. | |||||||||
Transfer Time | AC Mode to Batt. Mode | Zero | |||||||||
Waveform(Batt. Mode) ) | Pure Sinewave | ||||||||||
Efficiency | |||||||||||
Battery Mode | 85% | 92% | 92% | ||||||||
Battery | |||||||||||
Battery Type | 12 V/7 Ah | Depending on applications | 12 V/7 Ah | Depending on applications | 12 V/7 Ah | Depending on applications | 12 V/7 Ah | Depending on applications | 12 V/7 Ah | Depending on applications | |
Battery Numbers | 2 | 4 | 6 | 16 | 16 | ||||||
Recharge Time | 8 hours recover to 90% capacity | 9 hours recover to 90% capacity | |||||||||
Charging Current | 1 A | 6.5A | 1 A | 5.5A | 1 A | 5.5A | 1 A | 5.5A | 1 A | 5.5A | |
Environment | |||||||||||
Operation Humidity | 20-90% RH @ 0-40℃ Non-condensing | 0-95% RH @ 0-50℃ Non-condensing | 0-95% RH @ 0-40℃ Non-condensing | ||||||||
Noise Level | Less than 50dBA @ 1 Meter | Less than 55dBA @1 Meter | Less than 58dBA @1Meter | ||||||||
Management | |||||||||||
Smart RS-232 | Support windows® 2000/2003/XP/Vista/2008, windows® 7/8, Linux, Unix and MAC | ||||||||||
Optional SNMP | Power management from SNMP management and web browser |
Front view
Rear Panel